Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.
Vapors from liquefied gas are initially heavier than air and spread along ground.
Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite.
Fire may produce irritating, corrosive and/or toxic gases.
Fire or explosion
Some may burn but none ignite readily.
Containers may explode when heated.
Ruptured cylinders may rocket.
CAUTION: Aerosols (UN1950) may contain a flammable propellant.
◆
Public Safety
General
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
Keep unauthorized personnel away.
Stay upwind, uphill and/or upstream.
Many gases are heavier than air and will spread along the ground and collect in low or confined areas (sewers, basements, tanks, etc.).
Ventilate closed spaces before entering, but only if properly trained and equipped.
Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE.
Structural firefighters' protective clothing provides thermal protection but only limited chemical protection.
Evacuation
Immediate precautionary measure
Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
Large Spill
Consider initial downwind evacuation for at least 500 meters (1/3 mile).
Fire
If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.
↯
Emergency Response
Fire
Use extinguishing agent suitable for type of surrounding fire.
Small Fire
Dry chemical or CO2.
Large Fire
Water spray, fog or regular foam.
If it can be done safely, move undamaged containers away from the area around the fire.
Damaged cylinders should be handled only by specialists.
Fire Involving Tanks
Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles.
Cool containers with flooding quantities of water until well after fire is out.
Do not direct water at source of leak or safety devices; icing may occur.
Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank.
ALWAYS stay away from tanks in direct contact with flames.
Some of these materials, if spilled, may evaporate leaving a flammable residue.
Spill or leak
Do not touch or walk through spilled material.
Stop leak if you can do it without risk.
Do not direct water at spill or source of leak.
Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.
If possible, turn leaking containers so that gas escapes rather than liquid.
Prevent entry into waterways, sewers, basements or confined areas.
Allow substance to evaporate.
Ventilate the area.
+
First Aid
Refer to the “General First Aid” section.
Specific First Aid:
In case of contact with liquefied gas, only medical personnel should attempt thawing frosted parts.